TRANSTIG 300 AC/DC
January 16, 2008
11-1
SECTION 11:
VOLTAGE REDUCTION DEVICE (VRD)
11.01 VRD SPECIFICATION
TransTIG
Description 300 AC/DC Notes
VRD Open Circuit Voltage 15.3 to 19.8V Open circuit voltage between welding
terminals.
VRD Resistance 148 to 193 ohms The required resistance between
welding terminals to turn ON the
welding power.
VRD Turn OFF Time 0.2 to 0.3
seconds
The time taken to turn OFF the welding
power once the welding current has
stopped.
Table 11-1: VRD Specification
11.02 VRD MAINTENANCE
Routine inspection and testing (power source):
An inspection of the power source, an insulation resistance test and an earth resistance test should be carried
out.
a. For transportable equipment, at least once every 3 months.
b. For fixed equipment, at least once every 12 months.
The owners of the equipment shall keep a suitable record of the periodic tests.
NOTE
A transportable power source is any equipment that is not permanently connected and fixed in the
position in which it is operated.
In addition to the above tests and specifically in relation to the VRD fitted to this machine, the following
periodic tests should also be conducted by an accredited Cigweld Service Provider.
Description Required Parameters
VRD Open Circuit Voltage Less than 20V; at Vin=415V
VRD Turn ON Resistance Less than 200 ohms
VRD Turn OFF Time Less than 0.3 seconds
Table 11-2: Periodic Tests
If this equipment is used in a location or an environment with a high risk of electrocution then the above tests
should be carried out prior to entering this location.